RAID 50
fortunalg

RAID

0

1

3

5

6

0+1

1+0 (10)

30

50

RAID 50

Mirroring and Striping across multiple RAID levels

RAID 50 is a combination of RAID level 5 and RAID level 0. RAID 50 includes both parity and disk striping across multiple drives. RAID 50 is best implemented across two RAID 5 arrays with data striped across both disk arrays. RAID 50 breaks the data into smaller blocks, and then stripes the blocks to each RAID 5 raid set. RAID 5 breaks up data into smaller blocks, calculates parity by performing and Exclusive OR on the blocks, and then writes the blocks of data and parity to each drive in the array. The size of each block is determined by the stripe size parameter, which is set when the RAID is created.

Advantages

RAID 50 can sustain one to four drive failures while maintaining data integrity if each failed disk is in a different RAID 5 array.

Offers highest level of redundancy and performance

Disadvantages

Very costly to implement

RAID 50

Application

Data warehousing

[Home] [SCSI - SATA RAID] [FC - SATA RAID] [SCSI - SCSI RAID] [FW - USB RAID] [SATA Disk Drives] [SAS disk drives] [RAID explained] [RAID levels] [RAID 0] [RAID 1] [RAID 3] [RAID 5] [RAID 6] [RAID 0+1] [RAID 10] [RAID 30] [RAID 50] [Warranty] [Information form] [About us] [Contact us] [Purchase online] [Website links] [Resellers] [Terminology]